Ticket #10483 (closed defect: fixed)

Opened 3 years ago

Last modified 3 years ago

Incorrect EC host power off on next boot after battery critical shutoff

Reported by: rsmith Owned by: rsmith
Priority: normal Milestone: Not Triaged
Component: embedded controller Version: 1.5/1.0 Software Build os852 aka 10.1.2
Keywords: Cc:
Action Needed: no action Verified: no
Deployments affected: Blocked By:
Blocking:

Description

In XO 1.5 EC versions 1.9.32 - 2.0.0 if shutoff from critical low battery occurs and the EC stays powered then the next power up cycle will power down shortly after the firmware screen.

The fix for this is in EC 2.0.1

Change History

Changed 3 years ago by Quozl

Released in Q3A61. A test underway.

Changed 3 years ago by Quozl

  • status changed from new to closed
  • next_action changed from package to no action
  • resolution set to fixed
  • version changed from not specified to 1.5/1.0 Software Build os852 aka 10.1.2

Verified, did not reproduce on EC 2.0.1, closing.