Ticket #10483 (closed defect: fixed)
Incorrect EC host power off on next boot after battery critical shutoff
| Reported by: | rsmith | Owned by: | rsmith |
|---|---|---|---|
| Priority: | normal | Milestone: | Not Triaged |
| Component: | embedded controller | Version: | 1.5/1.0 Software Build os852 aka 10.1.2 |
| Keywords: | Cc: | ||
| Action Needed: | no action | Verified: | no |
| Deployments affected: | Blocked By: | ||
| Blocking: |
Description
In XO 1.5 EC versions 1.9.32 - 2.0.0 if shutoff from critical low battery occurs and the EC stays powered then the next power up cycle will power down shortly after the firmware screen.
The fix for this is in EC 2.0.1