Opened 9 years ago

Closed 9 years ago

Last modified 4 months ago

#1051 closed defect (fixed)

LiFe batteries incorrectly flash red light.

Reported by: cjb Owned by: rsmith
Priority: high Milestone:
Component: embedded controller Version:
Keywords: relnote Cc:
Blocked By: Blocking:
Deployments affected: Action Needed:
Verified: yes


Can be reset by removing/reinserting the battery.

Attachments (1)

readEC (6.4 KB) - added by David.Lin 9 years ago.
show the EC RAM

Download all attachments as: .zip

Change History (6)

Changed 9 years ago by David.Lin

show the EC RAM

comment:1 Changed 9 years ago by David.Lin

It looks like the battery is broken.
Please use the readEC to dump the data.

  1. readEC fb00
  2. readEC f900

Then I can tell you what’s wrong.

comment:2 Changed 9 years ago by jg

  • Keywords relnote added

comment:3 Changed 9 years ago by jg

  • Milestone changed from Trial-1 to BTest-3

comment:4 Changed 9 years ago by jg

  • Resolution set to fixed
  • Status changed from new to closed

This is fixed in firmware version Q2B87.

comment:5 Changed 4 months ago by Quozl

  • Milestone BTest-3 deleted

Milestone BTest-3 deleted