Ticket #11493 (closed enhancement: fixed)

Opened 2 years ago

Last modified 2 years ago

XO-1.75 AP and CP tags

Reported by: Quozl Owned by: Quozl
Priority: normal Milestone: 1.75-firmware
Component: ofw - open firmware Version: Development firmware
Keywords: Cc:
Action Needed: no action Verified: no
Deployments affected: Blocked By:
Blocking:

Description

AP and CP tags do not appear to work at Q4C05 and 0.3.05, the tags can be set, but the EC does not respond by turning on laptop in response to cold boot.

The code is in EC, OFW properly avoids the tags area on write to EC over EDI, but:

- OFW does not write to the EC tags area when the CP or AP tags are changed, and

- OFW does not avoid the tags area on verify of EC over EDI.

Or, I'm just misunderstanding things.

Change History

Changed 2 years ago by Quozl

  • next_action changed from design to testcase

Fixed in svn 2706, OFW does write to EC flags area if CP and AP tags are changed, and OFW does avoid the flags area on verify.

Changed 2 years ago by Quozl

  • next_action changed from testcase to test in build

Released in Q4C06.

Changed 2 years ago by Quozl

  • status changed from new to closed
  • next_action changed from test in build to no action
  • resolution set to fixed

Tested Q4C12, closing.