Opened 3 years ago

Closed 3 years ago

#11493 closed enhancement (fixed)

XO-1.75 AP and CP tags

Reported by: Quozl Owned by: Quozl
Priority: normal Milestone: 1.75-firmware
Component: ofw - open firmware Version: Development firmware
Keywords: Cc:
Blocked By: Blocking:
Deployments affected: Action Needed: no action
Verified: no

Description

AP and CP tags do not appear to work at Q4C05 and 0.3.05, the tags can be set, but the EC does not respond by turning on laptop in response to cold boot.

The code is in EC, OFW properly avoids the tags area on write to EC over EDI, but:

  • OFW does not write to the EC tags area when the CP or AP tags are changed, and
  • OFW does not avoid the tags area on verify of EC over EDI.

Or, I'm just misunderstanding things.

Change History (3)

comment:1 Changed 3 years ago by Quozl

  • Action Needed changed from design to testcase

Fixed in svn 2706, OFW does write to EC flags area if CP and AP tags are changed, and OFW does avoid the flags area on verify.

comment:2 Changed 3 years ago by Quozl

  • Action Needed changed from testcase to test in build

Released in Q4C06.

comment:3 Changed 3 years ago by Quozl

  • Action Needed changed from test in build to no action
  • Resolution set to fixed
  • Status changed from new to closed

Tested Q4C12, closing.