Battery meter differences between Linux and OFW

Reported by: greenfeld Owned by: pbrobinson
Priority: normal Milestone: 12.1.0
Component: distro Version: Development build as of this date
Keywords: Cc: dsd
Action Needed: no action Verified: no
Deployments affected: Blocked By:
Blocking:

Description

With 11.3.1 (released build) on a XO-1.5, the battery percentage remaining shown in Sugar & GNOME will go up and down depending on if the XO is plugged in or not. This percentage also tends to have a bit of a fast falloff immediately after the XO is unplugged which slowly levels off.

OFW & olpc-logbat (showing the EC's output) show a different available battery reading than Sugar/GNOME do, and do not seem to have these sudden jumps.

Change History

Changed 2 years ago by greenfeld

  • cc dsd added
  • summary changed from 11.3.1 battery meter differences between Linux and OFW to Battery meter differences between Linux and OFW

This is also present in 12.1.0 os15.

Changed 2 years ago by pgf

  • next_action changed from diagnose to package

we were missing a commit which added POWER_SUPPLY_VOLTAGE_MAX_DESIGN=6500000 and changed POWER_SUPPLY_CHARGE_FULL_DESIGN=3100000 to 2800000. this fixes the problem.

Changed 2 years ago by dsd

  • next_action changed from package to add to build
  • milestone changed from Not Triaged to 12.1.0

Thanks, queued for 12.1.0 build 16

Changed 2 years ago by dsd

  • next_action changed from add to build to test in build

Test in 12.1.0 build 16.

Changed 2 years ago by greenfeld

  • status changed from new to closed
  • next_action changed from test in build to no action
  • resolution set to fixed

XO-1 and XO-1.5 report the same power readings via olpc-logbat and in Sugar in 12.1.0 os16.