XO-1.5 battery temperature display wrong

Reported by: Quozl Owned by: Quozl
Priority: normal Milestone: 1.5-firmware
Component: ofw - open firmware Version: Development firmware
Keywords: Cc:
Action Needed: no action Verified: no
Deployments affected: Blocked By:
Blocking:

Description

Following r3400, a 33C battery temperature is reported as 80C by .bat and watch-battery.

Change History

Changed 17 months ago by rsmith

  • next_action changed from diagnose to package

Fixed in r3466.

Changed 16 months ago by Quozl

  • owner changed from rsmith to Quozl
  • status changed from new to assigned

Changed 14 months ago by Quozl

  • status changed from assigned to closed
  • next_action changed from package to no action
  • resolution set to fixed

Fixed in Q3C11.