Ticket #2877 (new defect)

Opened 3 years ago

Last modified 3 years ago

Antennae connector plating and shavings.

Reported by: jg Owned by: vance.ke
Priority: normal Milestone: 8.2.0 (was Update.2)
Component: manufacturing process Version: 1.0-hardware-B4
Keywords: Cc: mlj, danerogers
Action Needed: Verified: no
Deployments affected: Blocked By:
Blocking:

Description

Beginning with the WiFi antenna connectors. There were two ombinations. The connectors on the board were always gold plated. There were two different vendors for the female connector used on the cable, one was gold plated and one looked tin plated.

Of the four machines with a tin on gold connector combination, there were six metal slivers in or around the ANT1 and ANT2 connectors on the board. These slivers appear to be shavings of plating material. Of the six machines using gold on gold connectors, only two very small slivers were found. These clearly caused no problems but they do have the potential to do so.

http://wiki.laptop.org/images/2/25/OLPC_BR_Audit.pdf

Attachments

cl1 antenna conn Scrapt.ppt (1.4 MB) - added by arnold 3 years ago.
Antenna connector test report

Change History

Changed 3 years ago by jg

  • cc danerogers added

Changed 3 years ago by arnold

The antenna vendor did the mating /unmating test 25cycles, there was plating scraps issues found, but connector function is still OK. Please see the attachment for the detail report.

Changed 3 years ago by arnold

Antenna connector test report

Note: See TracTickets for help on using tickets.